DEPCA Switch Settings +----------------------------------------------------------+ |W17 | | . . | | . W16. . | | W15. | | ...... | | . . . ...... | | . . . ...... | | W6-8 W9-14 | | ..... | | ..... | | ..... | | W1-5 | | | +------------------------------------+ | | | +---------------------+ Jumper Default Function W1 Top IRQ2 W2 Bottom IRQ3 W3 Removed IRQ4 W4 Removed IRQ5 W5 Removed IRQ7 Note: Only two jumpers can be install at any time. One in the top position and one in the bottom. The top selects the IRQ for the mouse controller and the bottom for the Network controller. W6 Installed I/O Address Select (300-30F) Removed = (200-20F) W7 Installed Memory Address Select W8 Installed Buffer Size Select W7 W8 Mode Memory Starting Address IN IN 64 Kbyte D0000 (Primary) OUT IN 64 Kbyte E0000 (Secondary) IN OUT 32 Kbyte D8000 (Primary) OUT OUT 32 Kbyte C8000 (Secondary) W9 Bottom AUI/Mau Select W10 Bottom AUI/Mau Select W11 Bottom AUI/Mau Select W12 Bottom AUI/Mau Select W13 Bottom AUI/Mau Select W14 Bottom AUI/Mau Select Note: Place W9-14 Bottom position for Thinwire and top for Ethernet AUI. W15 Installed Installed for IEEE 802.3 Compliance Note: Remove W15 if cable has 9 pins. W16 Remote Boot Enable W17 DC/DC Converter Enable Note: Remove W17 for Ethernet AUI.