Event log message on HSG80 console:
%EVL--HSG--24-JAN-2003 14:47:13-- Instance Code: 030C4002
Template: 81.(51)
Occurred on 24-JAN-2003 at 14:47:13
Power On Time: 0. Years, 134. Days, 11. Hours, 58. Minutes, 56. Seconds
Controller Model: HSG80
Serial Number: ZG02804764 Hardware Version: E12(2A)
Software Version: V86F-10(BA)
Unit Number: 111.(006F)
Unit Software Version: 1.(01) Unit Hardware Version: 56.(38)
Retry Level: 1. Retries: 0.
Port: 1. Target: 11. LUN: 0.
SCSI Device Type: 31.(1F)
Device ID: "BD03664553" Device Serial Number: "2248CD8W"
Device Software Revision Level: "3B08"
SCSI Command Opcode: 0.(00)
Sense Data Qualifiers: 0.(00)
SCSI Sense Data:
Error Code: 0.(00) {reserved}
Information field is invalid
Segment: 0.(00)
Sense Key: 4.(04) HARDWARE ERROR
ILI: 0 EOM: 0 FM: 0
Information: 00000000
Additional Sense Length: 0.(00)
Command-Specific Information: 00000000
ASC: 63.(3F) ASCQ: 133.(85)
FRU: 0.(00) Sense-Key Specific: 000000
Instance Code: 030C4002