 |
» |
|
|
 |
This appendix explains the steps required to
enable your system to boot over the LAN using the OpenVMS InfoServer
utility, a software application available on OpenVMS Alpha (Version
8.3 or later) and OpenVMS I64 (Version 8.2-1 or later) systems. It
also describes how to boot the virtual DVD/CD drive from the network. InfoServer
network booting is supported for OpenVMS installations and upgrades
on any OpenVMS Alpha system and on any Integrity servers that support
OpenVMS. For OpenVMS I64 systems, InfoServer network booting is supported
on all LAN cards (also referred to as LAN devices or adapters) that
are supported by EFI. You can use the OpenVMS InfoServer software application
on all Version 8.2-1 or later OpenVMS I64 systems as well as on any
OpenVMS Alpha Version 8.3 systems that support a DVD drive. This
support provides the additional advantage of allowing a network administrator
to boot multiple OpenVMS systems on the network from a single copy
of the OpenVMS distribution CD or DVD. Using the InfoServer utility on Integrity servers
for network booting requires several one-time-only configuration steps
unique to OpenVMS I64. Likewise, using the InfoServer utility on
OpenVMS Alpha servers requires an additional, one-time-only software
configuration step. Any configuration procedures that might have
been performed for network booting using an InfoServer hardware system
(traditionally used by Alpha systems) are not valid for the OpenVMS InfoServer application. Booting from the InfoServer utility for OpenVMS
I64 on Integrity servers differs significantly from booting from the
InfoServer hardware system traditionally used by OpenVMS Alpha systems
or from the InfoServer utility on OpenVMS Alpha systems. For example,
while Alpha systems use the Maintenance Operations Protocol (MOP)
to request the primary bootstrap file (APB.EXE) to start the boot,
the Integrity server console uses the Intel® Preboot Execution Environment (PXE) bootstrap protocol
in conjunction with the TCP/IP Services for OpenVMS BOOTP server and
TFTP. The Integrity server EFI console first loads the primary bootstrap
file VMS_LOADER.EFI, which is formatted for EFI compatibility. VMS_LOADER.EFI
then uses TFTP to request the primary bootstrap IPB.EXE from the boot server. IPB.EXE is formatted in OpenVMS ODS file
structure and is needed for booting the OpenVMS I64 operating system. To install or upgrade the operating system over
the network, OpenVMS I64 systems must use the InfoServer utility that
is integrated with the OpenVMS operating system. The InfoServer hardware
traditionally used by OpenVMS Alpha systems is not equipped to handle
DVD drives required for the OpenVMS I64 distribution media. Table B-1 summarizes the major differences
between Alpha and I64 InfoServer booting. Table B-1 InfoServer Booting: Differences Between Alpha and I64 Systems | Component | Alpha | I64 |
|---|
| Downline
load protocol | MOP | PXE (DHCP/BOOTP/TFTP) | | Boot file | APB_version (for
example, APB_083) | VMS_LOADER.EFI and IPB.EXE
(both files are version specific) | | Boot server | Any MOP-enabled system with the specified
file | Only those BOOTP servers having the
network device MAC address defined in the BOOTP database | | LAN server | InfoServer hardware, or InfoServer utility
running on OpenVMS Alpha Version 8.3 or later, or on OpenVMS I64 Version
8.2-1 or later | InfoServer application running
on OpenVMS Alpha Version 8.3 or OpenVMS I64 Version 8.2-1 or later |
Because of these differences, any procedures used
for Alpha systems to set up booting from the InfoServer hardware are
not valid for setting up booting from the OpenVMS InfoServer utility.
In addition, actions for setting up booting from the OpenVMS I64
InfoServer utility differ from those required for setting up booting
from an OpenVMS Alpha InfoServer utility. Table B-2 lists the various actions that need to be performed
to enable network booting using the OpenVMS InfoServer utility on
OpenVMS I64 or OpenVMS Alpha systems. These actions need be performed
only once except where noted. Table B-2 Procedure for Enabling InfoServer Network Booting | InfoServer Client Setup | | | Architecture | Actions Required | Section | I64 clients only | Determine the LAN I/O card to be used on your local
Integrity server for the network boot and report the associated OpenVMS
device name, its IP address, and its MAC address to the network administrator
responsible for setting up the BOOTP server. Optionally (and recommended), add this network device
as an EFI boot option—this procedure can be repeated on any
other system in the LAN that will use the InfoServer server for network
booting. Verify that the network device is supported by EFI
as a bootable device.
| Section B.2 | | InfoServer Utility Setup | | | Architecture | Actions Required (You or Network Administrator) | Section | | I64 or Alpha | Designate at least one OpenVMS system in the LAN as the InfoServer
server. Upgrade the system if necessary (OpenVMS I64 must be Version
8.2-1 or later; OpenVMS Alpha must be Version 8.3 or later). | Upgrade instructions in Chapter 6. Prior to
upgrading, review Chapter 4, and Chapter 5. | I64 or Alpha | Copy SYS$STARTUP:ESS$LAD_STARTUP.TEMPLATE
to SYS$STARTUP:ESS$LAD_STARTUP.DAT and then modify parameters
in SYS$STARTUP:ESS$LAD_STARTUP.DAT. Determine which network device will be used for InfoServer
LAD operations. Copy SYS$STARTUP:ESS$LAST_STARTUP.TEMPLATE to SYS$STARTUP:ESS$LAST_STARTUP.DAT
and then modify parameters in SYS$STARTUP:ESS$LAST_STARTUP.DAT. Add a line to SYS$MANAGER:SYSTARTUP_VMS.COM to start
the SYS$STARTUP:ESS$LAD_STARTUP.COM file at startup. If you changed any SYSGEN parameters, run AUTOGEN
and reboot; if you did not change SYSGEN parameters, skip the reboot
and execute the SYS$STARTUP:ESS$LAD_STARTUP.COM file manually. Use the InfoServer control program to create a service
for the DVD drive.
| Section B.3. | Alpha only | Enable MOP on the boot server and then copy APB_083.SYS
from the OpenVMS Version 8.3 distribution media to the MOP download
database (LAN$DLL, which defaults to MOM$SYSTEM). | See the LANCP chapter in HP OpenVMS System Management Utilities Reference Manual: A-L. | I64 only | Set up the TCP/IP Services for OpenVMS BOOTP server
and TFTP server. (For each new release of OpenVMS I64, update
the client entries in the BOOTP database to point to the new version-specific
boot file.) The person responsible for setting up the boot server
needs information about your InfoServer client. OpenVMS I64 boot
files are unique for each version of OpenVMS I64. Latest boot files
must be available and referenced in the BOOTP server database. | Section B.4. |
 |  |  |  |  | NOTE: The discussion of InfoServer booting in this manual
pertains to environments where the boot clients and servers are located
in the same LAN. For more complex circumstances, consult HP Customer
Support. |  |  |  |  |
To
set up your local OpenVMS I64 system as an InfoServer client for network
booting, you must perform the following steps. Detailed instructions
are provided in the subsections that follow. For OpenVMS Alpha systems,
no extra steps are required for setting up an InfoServer client. Determine
the LAN I/O card to be used on your local Integrity server for the
network boot. Report the associated OpenVMS device name and its IP
address and MAC address to the network administrator responsible for
setting up the BOOTP server. Optionally
(and recommended), add the network device as a boot option in the
EFI Boot Manager menu. Verify
that the network device is supported by EFI as a bootable device.
 |  |  |  |  | NOTE: The ability to boot over the network requires
that the nearest switch or router be configured to autonegotiate. |  |  |  |  |
B.2.1 Determining the Local Network I/O Card to Be Used |  |
Select a LAN I/O card (also referred to as a LAN
I/O device or adapter) on your Integrity server. This device must
be supported by your Integrity server’s EFI firmware. At minimum,
EFI supports the core I/O LAN cards installed
in the Integrity server. On all Integrity servers, devices supported
by OpenVMS are either EI or EW devices (for example, EIA0 or EWA0).
The EFI firmware might also support variants of the core I/O cards,
such as additional network interface cards (NICs) of the same type.
It might also support other NICs that are installed in the system
but not classified as core I/O cards. In any case, you can verify
that the device you select is supported by EFI. If multiple I/O cards are available on your system,
you can choose more than one to serve for network booting. To list the installed LAN I/O devices known to
your OpenVMS I64 system, follow these steps: If
your operating system is not running, access the OpenVMS DCL triple
dollar sign prompt ($$$) from your OpenVMS I64 OE DVD by selecting
option 8 (Execute DCL commands and procedures) on the OpenVMS operating
system main menu. Otherwise, skip to the next step. At
the DCL prompt, enter the following command to start the OpenVMS I64
Boot Manager utility. @SYS$MANAGER:BOOT_OPTIONS |
Start
the LANCP utility and enter the LANCP command SHOW CONFIGURATION at
the LANCP prompt, as in the following example. The resulting display
lists four LAN devices, two of which are available (connected), as
indicated by the Link column (Up means the device is available; Down
means it is not). You can use a device that is in use by other protocols.
Decide which available devices you want to use for network booting
and record the device’s name, MAC address, and IP address.
(The MAC address should be labeled on the physical device.) Once
the LAN device is verified as bootable by EFI, you provide this information
to the person responsible for maintaining the BOOTP server database
(see Section B.4).
 |
$$$ RUN SYS$SYSTEM:LANCP
LANCP> SHOW CONFIGURATION
LAN Configuration:
Parent or
Device PrefCPU Medium/User Version Link Speed Duplex Auto BufSize MAC Address Type ...
------ ------- ----------- ------- ---- ----- ------ ---- ------- ---------------- ------------ ...
EIA0 0 Ethernet X-21 Up 1000 Full Yes 1500 AA-00-04-00-A5-38 UTP i82546 ...
00-13-21-5B-85-E4 (default) ...
EIB0 1 Ethernet X-21 Up 1000 Full Yes 1500 AA-00-04-00-A5-38 UTP i82546 ...
00-13-21-5B-85-E5 (default) ...
EWA0 0 Ethernet X-59 Down - - Yes 1500 00-11-0A-43-23-D8 UTP AB465A ...
EWB0 1 Ethernet X-59 Down - - Yes 1500 00-11-0A-43-23-D9 UTP AB465A ... |
B.2.2 Adding the Network Boot Option to the EFI Boot Manager |  |
To add the LAN device (virtual DVD drive) as a
network boot option, use the OpenVMS I64 Boot Manager utility, as
follows: At
the DCL prompt, enter the following command to start the OpenVMS I64
Boot Manager utility: $ @SYS$MANAGER:BOOT_OPTIONS |
The
OpenVMS I64 Boot Manager Boot Options main menu is displayed. To
add a network boot option, enter 1 at the prompt:
OpenVMS I64 Boot Manager Boot Options List Management Utility
(1) ADD an entry to the Boot Options list
(2) DISPLAY the Boot Options list
(3) REMOVE an entry from the Boot Options list
(4) MOVE the position of an entry in the Boot Options list
(5) VALIDATE boot options and fix them as necessary
(6) Modify Boot Options TIMEOUT setting
(B) Set to operate on the Boot Device Options list
(D) Set to operate on the Dump Device Options list
(G) Set to operate on the Debug Device Options list
(E) EXIT from the Boot Manager utility
You can also enter Ctrl-Y at any time to abort this utility
Enter your choice: 1 |
 |  |  |  |  | NOTE: While using this utility, you can change a response
made to an earlier prompt by entering the caret (^) character as many
times as needed. To end and return to the DCL prompt, press Ctrl/Y. |  |  |  |  |
The
utility prompts you for the device name. Enter the device name.
In the following example, the device name is EIA0:. Enter the device name (enter "?" for a list of devices): EIA0: |
The
utility prompts you for the position you want your entry to take in
the EFI boot option list. Enter any position number other than 1.
(The number 1 position sets the device for automatic rebooting, which
is not desirable for upgrades.) Enter the desired position number (1,2,3,,,) of the entry.
To display the Boot Options list, enter "?" and press Return.
Position [1]: 4 |
The
utility prompts you for OpenVMS boot flags. By default, no flags
are set. Enter the OpenVMS flags (for example, 0,1), or accept the
default (NONE) to set no flags as in the following example: Enter the value for VMS_FLAGS in the form n,n.
VMS_FLAGS [NONE]: |
The
utility asks whether the device will be used for cluster satellite
booting. Answer NO as in the following example: Will EIA0 be used for cluster satellite boot? (Yes/No): NO |
(For
information about establishing a device for cluster satellite booting,
see the HP OpenVMS Version 8.3 New Features and Documentation Overview and the HP OpenVMS Cluster Systems manuals.) The
utility prompts you for a description to include with your boot option
entry. By default, the device name and MAC address is used as the
description. You can enter more descriptive information, as in the
following example. As shown in the display of boot entries that follows,
the device name and MAC address (without dashes) are included anyway
in the boot entry line. Enter a short description (do not include quotation marks).
Description ["EIA0"]: I64 UPGRADE VIA NET
efi$bcfg: eia0 (Boot0002) Option successfully added |
Using the utility to display
the devices at this point (selecting 2 on the main menu), you see
your device listed, as in the following example: Enter your choice: 2
To display all entries in the Boot Options list, press Return.
To display specific entries, enter the entry number or device name.
(Enter "?" for a list of devices):
EFI Boot Options list: Timeout = 10 secs.
----------------------------------------------------------------------------
01. DKB0 PCI(0|20|1|1) Scsi(Pun0,Lun0) "Boot VMS from DKB0" OPT
02. DKB200 PCI(0|20|1|1) Scsi(Pun2,Lun0) "Boot VMS from DKB200" OPT
03. VenHw(d65a6b8c-71e5-4df0-d2f009a9) "EFI Shell [Built-in]"
04. EIA0 PCI(0|0|2|0) Mac(0013215b85e4) "I64 Upgrade VIA NET"
----------------------------------------------------------------------------
4 entries found. |
Exit
the utility by entering E at the prompt:
B.2.3 Verifying the Network I/O Device Is Bootable by EFI |  |
Finally, verify that the LAN device you selected
for your system’s InfoServer client is bootable by EFI. Verification
is recommended if the selected device is not one of the core I/O LAN
devices installed on your Integrity server. To verify that the selected
LAN device is bootable by EFI, follow these steps: Access
the EFI console for your Integrity server. If your operating system
is running, you must shut down your system to access EFI. (For details
about accessing and using EFI, see your hardware documentation.) From
the EFI main menu, select the Boot Configuration option (or in some
versions of EFI, the Boot Option Maintenance Menu). Make a selection
before the EFI timeout expires; otherwise, the first entry of the
EFI Boot Manager is selected automatically. If you are brought to
the EFI Shell prompt, enter the exit command at
the prompt to move back to the EFI main menu. If an autoboot begins,
you can perform a cold reset of the Integrity server to get back to
the EFI console. (For more information, see your hardware documentation.)
Otherwise, you must wait for your system to boot and shut it down
again. At
the EFI Boot Configuration menu, select the Boot From a File option.
In the Boot From a File list, look for the load file that corresponds
to the LAN device you selected for network booting. This is the load
file with a matching MAC address, as in the following example: Load File [Acpi(HWP0002,0)/Pci(2|0)/Mac(0013215b85e4)] |
The MAC address of the EIA0 network
device selected earlier was 00-13-21-5B-85-E4, which matches the MAC
address shown (without dashes). This verifies that the selected device
is visible to the EFI console. If none of the Boot From a File options
listed matches your selected device, then try another available device
(as listed with the LANCP command SHOW CONFIGURATION in Section B.2.1). Provide
the device name and its IP address and MAC address to the person responsible
for setting up the BOOTP server.
At least one system in the LAN must be designated
as the InfoServer server. This is the system that hosts the physical
DVD drive from which network booting is performed. This system must
be running OpenVMS I64 Version 8.2-1 or later or OpenVMS Alpha Version
8.3 or later. The InfoServer software comes as part of the base operating
system on these systems. The following steps are necessary to set up the
InfoServer software on the designated system: Copy
SYS$STARTUP:ESS$LAD_STARTUP.TEMPLATE to ESS$LAD_STARTUP.DAT (save
the ESS$LAD_STARTUP.TEMPLATE file as a backup). Edit
SYS$STARTUP:ESS$LAD_STARTUP.DAT to modify parameters as needed. This
file configures InfoServer parameters affecting the OpenVMS LASTport/Disk™ (LAD) server, which allows access to the
DVD drive. The following is an example of the configuration file
(with default settings):  |
!++
! ESS$LAD_STARTUP.TEMPLATE
!
! Copy this file to SYS$STARTUP:ESS$LAD_STARTUP.DAT and edit it
! to suit your local situation.
!
! This file is used by SYS$STARTUP:ESS$LAD_STARTUP.COM to set up
! the parameters for the InfoServer Application on OpenVMS
! LASTport/Disk (LAD) server.
!
! Note:
! The LAD disk block cache is structured as a number of fixed-size
! buckets. You must specify both the bucket size and the number of
! buckets for the cache.
!
! The LAD cache is allocated from non-paged pool and is in no way
! associated with the XFC cache. The total LAD cache size in bytes
! may be determined by the formula:
!
! cache-bytes = bucket-size-in-blocks * number-of-buckets * 512
!
! Be sure the SYSGEN parameters NPAGDYN/NPAGEVIR are sized appropriately.
!
! The following keywords with values are accepted by this procedure:
!
! BUFFER_SIZE - A number between 3 and 8 denoting the
! bucket size in blocks as follows:
! 3 - 8 blocks
! 4 - 16 blocks
! 5 - 32 blocks
! 6 - 64 blocks
! 7 - 128 blocks
! 8 - 256 blocks
! CACHE_BUCKETS - Number of buckets
! MAXIMUM_SERVICES - Maximum number of services (max=1024)
! WRITE_LIMIT - Server wide count of asynchronous writes
!--
BUFFER_SIZE = 3 ! default (8 block buckets)
CACHE_BUCKETS = 512 ! Default setting
WRITE_LIMIT = 0 ! No async writes
MAXIMUM_SERVICES = 256 ! default (typically more than enough) |
 |
The following table provides a short description
of each of the parameters: | Parameter | Description |
|---|
| BUFFER_SIZE | The InfoServer block cache is structured as an array
of fixed-size buffers (also called buckets). The BUFFER_SIZE parameter
determines the size of each buffer or bucket. The numeric value of
this parameter is an integer in the range 3 through 8, representing
the bucket size in 512-byte blocks as follows. Note that bucket sizes
larger than 32 blocks might not be appropriate for most users. The
OpenVMS client segments I/O requests larger than 31 blocks into 31-block
chunks, which could result in excessive I/O activity to the disk.
The cache is allocated from nonpaged pool and is dedicated solely
to the LAD driver. | | | 3 | 8 blocks (default) | | | 4 | 16 blocks | | 5 | 32 blocks | | 6 | 64 blocks | | 7 | 128 blocks | | 8 | 256 blocks | CACHE_BUCKETS | Determines the number of buckets in
the cache. The default is 512. Numbers larger than 16384 might adversely
affect performance. To reach a desirable cache size, consider increasing
the BUFFER_SIZE parameter. | MAXIMUM_SERVICES | Sets the maximum number of services
that can be defined at one time for the server. The value of this
parameter must be a power of 2. The default and minimum value is
256 (adequate for most circumstances); the maximum value is 1024.
Each service descriptor consumes nonpaged pool; however, unused services
consume 4 bytes each. | | WRITE_LIMIT | The number of asynchronous write operations that
can be outstanding for the server at any time. The default is 0 (no
outstanding asynchronous write operations). |
 |  |  |  |  | NOTE: As indicated in the file comments, the LAD cache
comes out of nonpaged pool. If you increase the cache significantly,
you might need to increase the nonpaged pool SYSGEN parameters (NPAGEDYN
and NPAGEVIR). |  |  |  |  |
Determine
which network device will be used for InfoServer LAD operations.
You can use any network device that is visible to OpenVMS. Typically,
any network device that works with DECnet or TCP/IP Services for OpenVMS
should work. Use the LANCP command SHOW CONFIGURATION to determine
which device to use, as described in Section B.2.1. For this release
of OpenVMS, the LASTport protocol runs on only a single network device.
To enable this device, copy the SYS$STARTUP:ESS$LAST_STARTUP.TEMPLATE
file to the SYS$STARTUP:ESS$LAST_STARTUP.DAT file, and then open the
SYS$STARTUP:ESS$LAST_STARTUP.DAT file and make the following changes: Remove
the comment character (!) from the line that has the following text:
DEVICE = (). Within the parentheses, specify the device name. For
example: DEVICE = (EIA). Comment
out the line that specifies ALL_CONTROLLERS = ON (comment out a line by inserting an exclamation point (!) at the
beginning of the line).
The following example shows the SYS$STARTUP:ESS$LAST_STARTUP.DAT
file with the suggested changes made (shown in bold): !++
! This file will be used to set the appropriate LASTCP qualifiers. The following
! LASTCP qualifiers: ALL_CONTROLLERS, CHECKSUM, TRANSMIT_QUOTA, or SLOW_MODE
! can be set by using the following statement format:
! LASTCP qualifier = 1 to enable e.g. SLOW_MODE = 1 enables SLOW_MODE
! LASTCP qualifier = 0 to disable e.g. SLOW_MODE = 0 disables SLOW_MODE
! The remaining LASTCP qualifiers will require the appropriate value settings.
DEVICE = (EIA) ! Uncommented; device name specified
! TIMEOUT = n minimum interval in seconds
! CIRCUIT_MAXIMUM = n maximum number of nodes
! GROUP = n Group number
! NODE_NAME = name Node name
! CONTROLLERS = ([{controller letter,}...]) Controller list
! TRANSMIT_QUOTA = n Number of transmit buffers
!--
!ALL_CONTROLLERS = ON ! Commented out |
Add
the following line to the system startup file SYS$MANAGER:SYSTARTUP_VMS.COM: @SYS$STARTUP:ESS$LAD_STARTUP.COM |
If
you changed any SYSGEN parameters, run AUTOGEN and reboot (for information
about running AUTOGEN, see Section 7.22). If no SYSGEN parameters were changed,
you can skip the reboot and execute the SYS$STARTUP:ESS$LAD_STARTUP.COM
file manually. After you complete these
steps, the InfoServer server software is running and available to
serve boot requests. Note that the network devices are LAD0 (the
LAD Server Virtual Device) and LAST0 (the LAST Transport Layer Virtual
Device). The
InfoServer server can run on the same system as the InfoServer client.
You might want to start the InfoServer client on this system, allowing
the system to mount InfoServer devices. To start the InfoServer on
this system, enter the following command at the DCL prompt: $$$ @SYS$STARTUP:ESS$STARTUP DISK |
To have the
InfoServer client start at system boot, include the command in SYS$MANAGER:SYSTARTUP_VMS.COM. Now
that you have set up and enabled the InfoServer server, you must use
the InfoServer control program to create a service for the DVD drive.
Follow these steps: Mount
the OpenVMS distribution media systemwide. In the following example,
DQA0 is the DVD drive name (typically, DQA0 or DNA0 is the drive name) and I640831H1 is the volume label (for OpenVMS
I64): $ MOUNT/SYSTEM DQA0 I640831H1 |
Enter
the following command at the DCL prompt to define the InfoServer control
program as a foreign command, or enter the line in a startup or login
command file: $ INFOSERVER :== $ESS$INFOSERVER |
Alternatively, you can enter the following command
to start the program: $ RUN SYS$SYSTEM:ESS$INFOSERVER |
Start
the InfoServer control program and create the service, as in the following
example (the colon after the device name DQA0 is required): $ INFOSERVER
INFOSERVER> CREATE SERVICE I640831H1 DQA0:
INFOSERVER> EXIT |
The created service should now be available for
any InfoServer clients in the same LAN (these clients broadcast service
solicitations over the LAN). Started as in this example, the InfoServer control
program accepts multiple commands until you exit by entering the EXIT
command (or pressing Ctrl/Z). You
can also enter a single command at the DCL prompt, returning you immediately
to the DCL prompt again: $ INFOSERVER CREATE SERVICE I640831H1 DQA0:
$ |
The InfoServer control program commands are similar,
though not identical, to those supported by the hardware InfoServer
used traditionally by OpenVMS Alpha systems. For more information,
see the INFOSERVER help (at the INFOSERVER prompt, type HELP) or the HP OpenVMS Version 8.3 New Features and Documentation Overview manual.
On
OpenVMS Alpha systems only, you must perform the following steps: Enable
MOP to use LANACP or DECnet on the system on which the OpenVMS InfoServer
utility is being used. For information about enabling MOP, see the
LANCP chapter in the HP OpenVMS System Management Utilities Reference Manual: A-L. Copy
the APB_083.SYS file from the OpenVMS Alpha distribution media to
the MOP download directory (LAN$DLL, which defaults to MOM$SYSTEM).
The BOOTP boot server for the OpenVMS I64 InfoServer
utility can be on the same system or on any system in the same LAN
as the InfoServer application. TFTP is required on the boot server
for supplying the boot files to the client systems. The steps necessary to set up the boot server
and boot files are as follows:  |  |  |  |  | NOTE: All instructions and examples assume the use of TCP/IP Services
for OpenVMS. Other IP products might work but have not been tested
and are not supported at this time. |  |  |  |  |
Make
sure TCP/IP Services for OpenVMS is installed and that: At least one IP interface is defined. The BOOTP server and TFTP server are configured and
started. Optionally, make sure TELNET and FTP are configured
and started.
To display IP interface
information, use the TCPIP SHOW INTERFACE command. To verify that the BOOTP and TFTP servers are
configured and started, use the HP TCP/IP Services for OpenVMS SYS$MANAGER:TCPIP$CONFIG.COM
configuration procedure. From the Main Configuration menu, select
option 3 (Server components). If a BOOTP or TFTP service is not enabled
and started, select the appropriate server option, and then enable
and start the service accordingly. For more information about configuring
and starting TCP/IP Services for OpenVMS components, see the HP TCP/IP Services for OpenVMS Installation and Configuration and HP TCP/IP Services for OpenVMS Management manuals.  |  |  |  |  | NOTE: If you are currently using the DHCP service, you
must disable it. The BOOTP service must be enabled instead. For
information about disabling or enabling services, see the HP TCP/IP Services for OpenVMS Management manual. |  |  |  |  |
Set
up a location for the OpenVMS I64 Version 8.3-1H1 boot files by
creating the directory accessible by TFTP, as in the following example.
(HP recommends that you create a separate boot file directory for
each version of the operating system.) $ CREATE/DIRECTORY TCPIP$TFTP_ROOT:[V831H1] |
 |  |  |  |  | IMPORTANT: For each subsequent upgrade of OpenVMS, you must
create a separate directory for the boot files specific to the OpenVMS
version and, where appropriate, modify the path specified for each
client’s boot files (as in step 6). To make subsequent upgrades easier, you can use systemwide or
clusterwide logical names. |  |  |  |  |
Copy
the following two files from the DVD to the TCPIP$TFTP_ROOT:[V831H1]
directory: [SYS0.SYSCOMMON.SYSEXE]VMS_LOADER.EFI [SYS0.SYSCOMMON.SYSEXE]IPB.EXE
Gather
data for each boot client (that is, each node that is going to boot
the DVD over the network), including the following information for
the client’s network device (the client Integrity server core
I/O card): Define
each boot client’s host name in the TCP/IP Services for OpenVMS
local host database using the TCPIP SET HOST command. In the following
example, hostname is the host name of the
boot client and ipaddress is its IP address. $ TCPIP SET HOST hostname/ADDRESS=ipaddress |
The IP address does not have
to be the actual address you plan to use for the boot client host;
it must be in the same LAN as the BOOTP server and must not be currently
in use. However, if you use statically assigned IP addresses, HP
recommends (for simplicity) using the assigned address of the boot
client’s network device. To display and verify the assigned IP address, use the TCPIP SHOW HOST command. For
each boot client, add an entry in the BOOTP database to associate
the MAC address of the client’s LAN device with the boot file
to be loaded from the boot server, as in the following example. In
this example, hostname is the host name of the
boot client, and MACaddress is the client’s
MAC address in the format xx-xx-xx-xx-xx; the
boot file specification need not include “TCPIP$TFTP_ROOT:”. $ TCPIP SET BOOTP hostname /HARDWARE=ADDRESS=MACaddress-
_$ /FILE=[V831H1]VMS_LOADER.EFI |
You might need to specify a gateway (/GATEWAYS) and
network mask (/NETWORK_MASK). To determine the names of the gateways
and the subnet information, consult your network administrator. For
more information about this command, see the TCP/IP Services for OpenVMS
documentation. To display and verify your BOOTP server configuration,
use the TCPIP SHOW BOOTP/FULL command.  |  |  |  |  | IMPORTANT: For each new version of OpenVMS I64, you must
modify the client entry in the BOOTP database to point to the new,
version-specific boot file. |  |  |  |  |
Example B-1 shows
the commands for setting up a boot server for a client named MOZART.
An explanation of each command follows the example. Example B-1 Setting Up the Boot Server and Client
$ CREATE/DIRECTORY TCPIP$TFTP_ROOT:[V831H1] 1
$ COPY DQA0:[SYS0.SYSCOMMON.SYSEXE]VMS_LOADER.EFI TCPIP$TFTP_ROOT:[V831H1]VMS_LOADER.EFI 2
$ COPY DQA0:[SYS0.SYSCOMMON.SYSEXE]IPB.EXE TCPIP$TFTP_ROOT:[V831H1]IPB.EXE 3
$ TCPIP SET HOST MOZART/ADDRESS=16.32.110.117 4
$ TCPIP SET BOOTP MOZART/HARDWARE=ADDRESS=00-13-21-5B-85-E4 -
_TCPIP> /FILE=[V831H1]VMS_LOADER.EFI 5
$ TCPIP SHOW HOST MOZART 6
BIND Database
Server: 15.227.128.41
Host address Host name
16.32.110.117 MOZART...
$TCPIP SHOW BOOTP MOZART/FULL 7
Host: 16.32.110.117 mozart
Hardware Address: 00-13-21-5B-85-E4
Network mask: 255.0.0.0 Type: Ethernet
File: [V831H1]VMS_LOADER.EFI
Time offset: 0
Vendor: ACME, Inc.
Gateways: not defined
Servers:
.
.
. |
| 1 | Creates the directory TCPIP$TFTP_ROOT:[V831H1]
on the system to be the TFTP and BOOTP server. | | 2 | Copies [SYS0.SYSCOMMON.SYSEXE]VMS_LOADER.EFI from
the DVD to TCPIP$TFTP_ROOT:[V831H1]. | | 3 | Copies [SYS0.SYSCOMMON.SYSEXE]IPB.EXE from the
DVD to TCPIP$TFTP_ROOT:[V831H1]. | | 4 | Adds the boot client host MOZART to the TCP/IP
hosts database, specifying MOZART’s IP address as 16.32.110.117. | | 5 | Adds host MOZART as a client entry in the BOOTP
database, where the MAC address of the client’s LAN device
is 00-13-21-5B-85-E4 (as was determined in the example for the client
in Section B.2.1) and the boot
file for the client is [V831H1]VMS_LOADER.EFI. | | 6 | Displays information about the boot client MOZART
as stored in the local host database (use this command to verify that
the client has been configured appropriately). | | 7 | Displays information about the boot client MOZART
as stored in the BOOTP database (use this command to verify that the
client has been configured appropriately). |
After you complete these steps, in addition to
the required steps in the preceding sections, you can boot a client
over the network using the InfoServer application. Instructions on
performing the InfoServer boot are in Section B.5. A troubleshooting section is included
in Section B.6. After
you set up the InfoServer software and the boot server properly and
ensure that the InfoServer service is available, you can boot the
remote DVD served by the InfoServer by following these steps:  |  |  |  |  | NOTE: You can copy the DVD to an LD device and boot
from the LD device. This process is faster than using a DVD. |  |  |  |  |
Make
sure the CD or DVD is mounted systemwide on the OpenVMS system serving
as the InfoServer, and make sure an InfoServer service for the DVD
drive is available on the network and accessible from your client
system (the system to be booted from the InfoServer). The service
should point to the server DVD drive on which the OpenVMS CD or DVD
is mounted. To ensure that the InfoServer service is available on
the network, use the following command: $ MC ESS$LADCP SHOW SERVICES |
The following is a sample display:
Interrogating network for Disk services, please wait...
.
.
.
Disk services offered by node MOOSIC (LAD V3.1, Address: AA-00-04-00-AB-4E)
Current Writes
Service: Device: Rating: Connects: Allowed?:
I640831H1 OpenVMS 65535 0 No
.
.
. |
In this example, the service I640831H1 is the
virtual disk unit that corresponds to the DVD drive on the InfoServer
server named MOOSIC. This is the drive from which the OpenVMS distribution
media is booted. The display shows that this service is available
and that a service binding to the InfoServer DVD drive is established. Access
EFI on your Integrity server. If you added a boot option for network
(InfoServer) booting to the EFI Boot Manager options list, as described
in Section B.2.2; then select
the appropriate boot option from the list. To move to the option,
use the up or down arrow key. (Depending on how your terminal emulator
is set up, you might have to use the letter v to scroll down or the
caret (^) to scroll up.) Press Enter to toggle the
selection. After selecting the boot option, skip to step 3.  |  |  |  |  | NOTE: If you do not select an option within the default 10-second
limit, the first option in the list is selected automatically. |  |  |  |  |
If you did not add a boot option
for InfoServer booting to the EFI Boot Manager options list, then
initiate the boot by either following the steps in “Booting with the EFI Boot Manager” or, on some of the more recent Integrity servers, using the simpler
method described in “Booting with
EFI lanboot select command”. Booting with the EFI Boot
ManagerFrom the EFI Boot Manager
screen, select the Boot Configuration option (or in some versions
of EFI, the Boot Option Maintenance Menu). From the EFI Boot Configuration
menu, select the Boot From a File option. The Boot From a File menu
lists the bootable devices (in EFI terminology, load files), including
their MAC addresses. The composition of the list depends on how your
Integrity server is set up. Select the appropriate device (search
for the correct MAC address). For example, the following load file
listed in the Boot From a File menu corresponds to the LAN device
with MAC address 00-13-21-5B-85-E4: Load File [Acpi(HWP0002,0)/Pci(2|0)/Mac(0013215b85e4)] |
Note that each device is identified by the unique
MAC address assigned to the device by the hardware vendor. Normally,
the MAC address is labeled on the physical device. See your hardware
documentation for more information. To further help you identify the LAN devices,
you can use the EFI pci command, which displays
all devices. Alternatively, you can try each of the LAN devices one
at a time until you find the right one. Finally, you can make sure
all LAN devices are connected to the appropriate network and are bootable
using the InfoServer, in which case it does not matter which one you
select. Note also that once you have OpenVMS running, you can display
the devices and their corresponding MAC addresses by using the LANCP
command SHOW CONFIG at the DCL prompt. The command lists the OpenVMS
device names along with the MAC address and other characteristics.
Likewise, with OpenVMS running, the EFI Utilities for OpenVMS vms_show command might provide additional information about
any devices on the local system.
Booting with EFI lanboot select commandFrom
the EFI Boot Manager screen, select the EFI Shell [Built-in] option. At the Shell prompt, enter
the lanboot select command. When prompted, enter the
number for the LAN device that has the MAC address specified when
you configured BOOTP in Section B.4.
When
you select the appropriate entry, you see several lines of messages
and then the InfoServer boot menu (the same boot menu you would see
on an Alpha system), as in the following example. The DHCP (Dynamic
Host Communication Protocol) message indicates the loading of the
loader image (VMS_LOADER.EFI) that uses the EFI console to load and
start the OpenVMS bootstrap (IPB.EXE). The Trivial File Transfer
Protocol (TFTP) loads the bootstrap. In this example, “I64
Upgrade VIA NET” is the boot option for the InfoServer service.
It was selected from the EFI Boot Manager options list (not shown).  |  |  |  |  | NOTE: If the InfoServer boot menu does not appear, you
have probably selected the wrong LAN device. Try selecting another
device. Verify the BOOTP database (see the HP TCP/IP Services for OpenVMS Management manual). Make sure the Integrity server that serves the network
drive is running. |  |  |  |  |
Loading.: Network Boot, 10/100
Running LoadFile()
CLIENT MAC ADDR: 00 13 21 5H 85 E4
DHCP./
CLIENT IP: 16.32.24.219 MASK: 255.0.0.0 DHCP IP: 0.240.0.0
Running LoadFile()
Starting: I64 Upgrade VIA NET
%EIA-I-BOOTDRIVER, Starting auto-negotiation
%EIA-I-BOOTDRIVER, Auto-negotiation selected 100BaseTX FDX
Network Initial System Load Function
Version 1.2
FUNCTION FUNCTION
ID
1 - Display Menu
2 - Help
3 - Choose Service
4 - Select Options
5 - Stop
Enter a function ID value: |
Respond
to the prompts by pressing Enter after each entry;
use the default service name indicated or one suggested by the system
manager: Enter
3 for the function ID. Enter
2 for the option ID. Enter
the service name ( I640831H1 is the
default service name for the OpenVMS I64 OE DVD; check
with your system or network manager for the service name to specify).
A sample display follows: Enter a function ID value: 3
OPTION OPTION
ID
1 - Find Services
2 - Enter known Service Name
Enter an Option ID value: 2
Enter a Known Service Name: I640831H1 |
After you boot, the system displays the OpenVMS
menu. To install your OpenVMS operating system, follow the instructions
in Section 3.3. To upgrade
your system, follow the instructions in Section 6.3.  |  |  |  |  | NOTE: If you boot the
OpenVMS OpenVMS I64 OE DVD from an InfoServer but lose your connection during
the installation or upgrade procedure (the system is unresponsive
and pressing Ctrl/Y does not return
you to the menu), do the following:| IF ... | THEN ... |
|---|
You previously chose the INITIALIZE option | Reboot the OpenVMS CD DVD. Choose the install/upgrade option (1) on the menu
and perform the installation or upgrade procedure again.
| You previously chose the PRESERVE option | Reboot the OpenVMS CD or DVD. Enter the DCL environment by choosing option 8 on
the menu. Mount the device containing your backup copy of the
target disk and the device that is your target disk. Restore the backup copy of your target disk by entering
the appropriate BACKUP commands. (See Appendix E for complete information about using MOUNT
and BACKUP commands to restore a system disk.) Log out from the DCL environment. Choose the install/upgrade option (1) on the menu
and perform the installation or upgrade procedure again.
|
|  |  |  |  |
For problems using the OpenVMS I64 InfoServer
software for network booting, consider the following: When you attempt to boot over the network, check your
console display for the following: The IP address of the boot server that sends your
EFI console the OpenVMS I64 loader file (VMS_LOADER.EFI). If this
IP address is not as expected, your client host might be in the database
of the wrong boot server. Enter your client host IP address in the
database of the correct boot server (see step 5 of Section B.4), and remove your client from the database of any other boot servers. The version number of the IPB.EXE bootstrap file that
is loaded (for this release, the version should be 8.3-1H1). If
this version number is not the correct version of OpenVMS I64, a message
indicates there is a mismatch. The boot server might be the source
of the problem. Make sure that it is configured correctly. Make
sure the client entry in the boot server’s database has been
updated to point to the current version of the loader file (see step 3 and step
6 of Section B.4). Evidence that DHCP is not responding. If you do not
see a message indicating autonegotiation has been started, make sure
the closest network device or switch is set for autonegotiation.
If the network boot succeeds but your attempt to choose
a service or to display services at the InfoServer menu fails, a device
might be filtering the LASTport/Disk (LAD) protocol. This protocol
does not provide routing functions and only works within a LAN. If
filtering devices are used in an extended LAN, the devices must allow
this protocol (protocol type is 80-41) to pass through unfiltered
so that clients can access the InfoServer across the filtering device.
For LANCP and LANACP problems, see the HP OpenVMS System Manager's Manual, Volume 2: Tuning, Monitoring, and Complex Systems for more information.
|