HP OpenVMS Systemsask the wizard |
The Question is:
Dectem on a Vax/vms 4000-60 doesn't start... i get the folloging
decterm_error.log in my login directory:
$type decterm_error.log;1
DECterm (compiled at Feb 2 1994 22:35:53) error occurred on Wed Jul 7
10:53:41
1999
Text of error message:
%SYSTEM-F-ACCVIO, access violation, reason mask=01, virtual
address=203BFFF9, PC
=0003E8F0, PSL=03C00000
Mapped images...
BASE START END LENGTH IMAGE NAME
---- ----- --- ------ ----------
200 200 1e1ff 1dfff DECW$TERMINAL
31c200 31c200 367bff 4b9ff DECW$TERMINALSHR12
30e800 30e800 31c1ff d9ff DECW$XEXTLIBSHR
28ba00 28ba00 3065ff 7abff DECW$DXMLIBSHR12
306600 306600 30e7ff 81ff LBRSHR
276c00 276c00 28b9ff 14dff DECW$MRMLIBSHR12
168200 168200 276bff 10e9ff DECW$XMLIBSHR12
138a00 138a00 1681ff 2f7ff DECW$XTLIBSHRR5
a3800 a3800 133fff 907ff DECW$XLIBSHR
134000 134000 1389ff 49ff DECW$TRANSPORT_COMMON
5f400 5f400 775ff 181ff VAXCRTL
a1a00 a1a00 a37ff 1dff CMA$TIS_SHR
77600 77600 a19ff 2a3ff MTHRTL
5ea00 5ea00 5f3ff 9ff PTD$SERVICES_SHR
2c600 2c600 3bbff f5ff SECURESHR
3bc00 3bc00 5e9ff 22dff LIBRTL
1e200 1e200 2c5ff e3ff SECURESHRP
398c00 398c00 42b9ff 92dff DECC$SHR
42ba00 42ba00 42d1ff 17ff DECW$TRANSPORT_TCPIP
47ec00 47ec00 47ffff 13ff TRACE
480000 480000 4807ff 7ff DECW$TERMINALMSG
480800 480800 4847ff 3fff VAXCMSG
484800 484800 484dff 5ff DECW$XLIBMSG
484e00 484e00 485bff dff DECW$TRANSPORTMSG
485c00 485c00 4921ff c5ff DBGTBKMSG
IMAGE+offset of call Parameters at caller's level
-------------------- ----------------------------
LIBRTL+2cf0 203c0000
DECW$XTLIBSHRR5+1cb1c 203c0000
DECW$TERMINAL+17b8e 369686, 43
DECW$TERMINAL+a722 1, 369440, 369410
81a993fa 7ffe5e40, 7ff6b397, 7ffe5e0c, 7ffe5eb4, 1000028, 1
7ff6592e
Also i tryed to run:
$create/term/detach
and my DCL Command window lock's up.
How can i fix this?
Before upgrading from VMs 6.2 to 7.1 decterm was working.
Please help.
The Answer is : Please check for and acquire the DECwindows ECO kit for whichever version of DECwindows is in use here, and apply it -- most OpenVMS systems should be running a minimum of DECwindows V1.2-4 at present. Also check for and apply other mandatory ECO kits for OpenVMS, and check for and apply the current DEC C RTL and OpenVMS RTL kits. If the problem persists after the application of the ECO kit(s), please contact the Compaq Customer Support Center directly for assistance.
|