; ; INTER-IBEX Corp. Switzerland ; Richard Lebeda ; ; 06.02.1991 ; 0 ; 1.01______ ; EPB2001 ; V 1.0 - ALIAS-6x/ALIAS-7x ; AdapterId 06A51h AdapterName "IBEX SERCOM2" NumBytes 4 FixedResources pos[2]=X1XXXXXXb pos[3]=XX11111Xb NamedItem Prompt "memory bank 0" choice "memory bank 0 off" pos[0]=XXXX000Xb choice "Base address: 0A0000; 64k" pos[0]=XXXX001Xb mem 0A0000h - 0AFFFFh choice "Base address: 0B0000; 32k" pos[0]=XXXX010Xb mem 0B0000h - 0B7FFFh choice "Base address: 0C0000; 32k" pos[0]=XXXX011Xb mem 0C0000h - 0C7FFFh choice "Base address: 0C0000; 64k" pos[0]=XXXX100Xb mem 0C0000h - 0CFFFFh choice "Base address: 0C8000; 32k" pos[0]=XXXX101Xb mem 0C8000h - 0CFFFFh choice "Base address: 0D0000; 64k" pos[0]=XXXX110Xb mem 0D0000h - 0DFFFFh choice "Base address: 0D8000; 32k" pos[0]=XXXX111Xb mem 0D8000h - 0DFFFFh Help "The IBEX SERCOM2 micro channel interface may be configured for mem addresses. Use the F5=Previous and the F6=Next keys to change this assignment in the 'Change Configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." ; ; ; ; NamedItem Prompt "memory bank 1" choice "memory bank 0 off" pos[0]=X000XXXXb choice "Base address: 0A0000; 64k" pos[0]=X001XXXXb mem 0A0000h - 0AFFFFh choice "Base address: 0C4000; 16k" pos[0]=X010XXXXb mem 0C4000h - 0C7FFFh choice "Base address: 0CC000; 16k" pos[0]=X011XXXXb mem 0CC000h - 0CFFFFh choice "Base address: 0B0000; 32k" pos[0]=X100XXXXb mem 0B0000h - 0B7FFFh choice "Base address: 0C0000; 32k" pos[0]=X101XXXXb mem 0C0000h - 0C7FFFh choice "Base address: 0D0000; 32k" pos[0]=X110XXXXb mem 0D0000h - 0D7FFFh choice "Base address: 0D8000; 32k" pos[0]=X111XXXXb mem 0D8000h - 0DFFFFh Help "The IBEX SERCOM2 micro channel interface may be configured for mem addresses. Use the F5=Previous and the F6=Next keys to change this assignment in the 'Change Configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." ; ; ; ; NamedItem Prompt "SCC basis address (uses 4 bytes)" choice "Base address: 000380" pos[1]=XXXXX000b pos[3]=1XXXXXXXb io 000380h - 000383h choice "Base address: 000390" pos[1]=XXXXX001b pos[3]=1XXXXXXXb io 000390h - 000393h choice "Base address: 001380" pos[1]=XXXXX010b pos[3]=1XXXXXXXb io 001380h - 001383h choice "Base address: 004440" pos[1]=XXXXX011b pos[3]=1XXXXXXXb io 004440h - 004443h choice "Base address: 009D68" pos[1]=XXXXX100b pos[3]=1XXXXXXXb io 009D68h - 009D6Bh choice "Base address: 00A650" pos[1]=XXXXX101b pos[3]=1XXXXXXXb io 00A650h - 00A653h choice "Base address: 00C6CC" pos[1]=XXXXX110b pos[3]=1XXXXXXXb io 00C6CCh - 00C6CFh choice "Base address: 00EFF0" pos[1]=XXXXX111b pos[3]=1XXXXXXXb io 00EFF0h - 00EFF3h Help "The IBEX SERCOM2 micro channel interface may be configured for io addresses. Use the F5=Previous and the F6=Next keys to change this assignment in the 'Change Configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." ; ; ; NamedItem Prompt "selected IRQ line" choice "IRQ 3" pos[2]=XXXXX000b choice "IRQ 4" pos[2]=XXXXX001b choice "IRQ 5" pos[2]=XXXXX010b choice "IRQ 7" pos[2]=XXXXX011b choice "IRQ 10" pos[2]=XXXXX100b choice "IRQ 11" pos[2]=XXXXX101b choice "IRQ 12" pos[2]=XXXXX110b choice "IRQ 15" pos[2]=XXXXX111b Help "The IBEX SERCOM2 micro channel interface may be configured for switch control addresses. Use the F5=Previous and the F6=Next keys to change this assignment in the 'Change Configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." ; ; ; ; NamedItem Prompt "Interrupt enable" choice "on " pos[0]=1XXXXXXXb choice "off" pos[0]=0XXXXXXXb Help "The IBEX SERCOM2 micro channel interface may be configured for switch control addresses. Use the F5=Previous and the F6=Next keys to change this assignment in the 'Change Configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." ; ; ; ; NamedItem Prompt "watchdog or timer frequency" choice "21.3 ms" pos[2]=XX10XXXXb choice "42.7 ms" pos[2]=XX11XXXXb choice "5.3 ms " pos[2]=XX00XXXXb choice "10.7 ms" pos[2]=XX01XXXXb Help "The IBEX SERCOM2 micro channel interface may be configured for switch control addresses. Use the F5=Previous and the F6=Next keys to change this assignment in the 'Change Configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." ; ; ; ; NamedItem Prompt "number of wait states" choice "2 wait states" pos[1]=XX110XXXb choice "1 wait state " pos[1]=XX111XXXb choice "8 wait states" pos[1]=XX000XXXb choice "7 wait states" pos[1]=XX001XXXb choice "6 wait states" pos[1]=XX010XXXb choice "5 wait states" pos[1]=XX011XXXb choice "4 wait states" pos[1]=XX100XXXb choice "3 wait states" pos[1]=XX101XXXb Help "The IBEX SERCOM2 micro channel interface may be configured for switch control addresses. Use the F5=Previous and the F6=Next keys to change this assignment in the 'Change Configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." ; ; ; ; NamedItem Prompt "wait state generator enable" choice "on " pos[1]=X1XXXXXXb choice "off" pos[1]=X0XXXXXXb Help "The IBEX SERCOM2 micro channel interface may be configured for switch control addresses. Use the F5=Previous and the F6=Next keys to change this assignment in the 'Change Configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." ; ; ; ; NamedItem Prompt "watchdog/timer select" choice "timer " pos[1]=0XXXXXXXb choice "watchdog" pos[1]=1XXXXXXXb Help "The IBEX SERCOM2 micro channel interface may be configured for switch control addresses. Use the F5=Previous and the F6=Next keys to change this assignment in the 'Change Configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." ; ; ; ; NamedItem Prompt "controller clock frequency" choice "12.288 Mc" pos[2]=XXXX1XXXb choice "6.144 Mc " pos[2]=XXXX0XXXb Help "The IBEX SERCOM2 micro channel interface may be configured for switch control addresses. Use the F5=Previous and the F6=Next keys to change this assignment in the 'Change Configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." ; ; ; ; NamedItem Prompt "serial clock control" choice "pin 15 connected as input " pos[2]=1XXXXXXXb choice "pin 24 connected as output" pos[2]=0XXXXXXXb Help "The IBEX SERCOM2 micro channel interface may be configured for switch control addresses. Use the F5=Previous and the F6=Next keys to change this assignment in the 'Change Configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." ; ; ; ; NamedItem Prompt "memory bank organisation" choice "memory bank 0 only " pos[3]=XXXXXXX0b choice "memory bank 0 and 1 active" pos[3]=XXXXXXX1b Help "The IBEX SERCOM2 micro channel interface may be configured for switch control addresses. Use the F5=Previous and the F6=Next keys to change this assignment in the 'Change Configuration' window. Conflicting assignments are marked with an asterisk and must be changed to use the adapter." ; ; ; ;